20 XSEL
Expansion SIO board (dedicated General purpose type)
DeviceNet Connection Board CC-Link Connection Board
A board for connecting the XSEL controller to DeviceNet. A board for connecting the XSEL controller to CC-Link.
Description
Board for serial communications with external equipment.
This board has two port channels and implements three
communication modes using the supplied joint cable(s).
Model/
Specifications
IA-105-X-MW-A (for RS232C connection) (main unit + joint cable(1), 2 included)
IA-105-X-MW- B (for RS422 connection) (main unit + joint cable(2), 1 cable is supplied)
IA-105-X-MW- C (for RS485 connection) (main unit + joint cable(2), 1 cable is supplied)
1
1
100mm
1
9
11
8
10
SG
13
12
4
ER
5
ER
RS
3
3
SD
1
SD
6
DRDR
6
9
CS
CS
4
RS
7
XM2A−0901
XM2D−1501
SG
5
7
1
14
No.No.
2
RDRD
2
8
Joint cable Model: CB-ST-232J001
Controller side
Cable connection side
Wiring Diagram
Wiring Color
Signal
Wiring
AWG24
x 7-core
AWG24
x 7-core
Color
Orange, black dot
Orange, black dot
Light gray, black dot
Light gray, red dot
White, black dot
White, red dot
Yellow, black dot
Orange, black dot
Orange, black dot
Light gray, black dot
Light gray, red dot
White, black dot
White, red dot
Yellow, black dot
Signal
* Communication cables for external
devices are not supplied.
1m(1000mm)
50mm
11
8
10
9
15
14
SD+
13
12
TRM
5
2
RD-
4
RD+
3
1
SD-
6
7
No.
XM2D−1501
Joint cable Model: CB-ST-422J010
Controller side
Orange, black dot
Orange, red dot
White, black dot
Light gray, black dot
Light gray, red dot
No connector
Wiring Diagram
Wiring Color
Signal
AWG24
x 7-core
Orange, black dot
Orange, red dot
White, black dot
Light gray, black dot
Light gray, red dot
* Connect to a terminal block, etc.
Item
Number of I/O Points
Communication
Standard
Communication
Specification
Baud rate
Communication
Cable-side
connector
Communication
Power Supply
Communication
Power Supply Current
Number of Reserved
Nodes
Controller
1 board: 256 input points/256 output points *1 Only 1 board can be installed
Interface module certified under DeviceNet 2.0 (certification to be obtained)
Group 2 only server
Network Insulated node operating on network power supply
Controller
500k/250k/125kbps (Selectable by DIP switch)
*When large DeviceNet cable is used
24VDC (supplied from DeviceNet)
60mA or higher
1
MSTBA2.5/5-G.08AUM by Phoenix Contact (*1)
Specifications
Baud rate
500kbps
250kbps
125kbps
Max. network length
100m
250m
500m
Max. branch length
6m
Total branch length
39m
78m
156m
Bit strobe
Polling
Cyclic
(*1) Cable-side connector Controller (Controller SMSTB2.5/5-ST-5.08AU) is a standard accessory.
Item
Communication
Standard
Baud rate
Communication method
Asynchronous
Encoding Format
Transmission path type
Transmission
formaterror
Control method
Number of Reserved
Stations
Communication
cablelength
Controller
(Controller-side)
Remote
Device
1 board: 256 inputs/256 outputs *Only 1 board can be installed
CC-Link Ver1.10 (already certified)
10M/5M/2.5M/625k/156kbps (Switched via the rotary switch)
Broadcast polling method
Frame synchronization method
NRZI
Bus Format (EIA RS485 Compliant)
HDLC Compliant
CRC(X
16
+X
12
+X
5
+X1)
1 to 3 stations (Remote device station)
MSTBA2.5/5-G-5.08-AUM made by Phoenix Contact (*1)
Specifications
Baud rate (bps)
Cable Length (m)
10M
100
5M
160
2.5M
400
625k
900
156k
1200
(*1) Cable-side connector (Made by Phoenix Contact SMSTB2.5/5-ST-5.08AU) is a standard accessory.
Option
Number of
I/O Points