Mitsubishi MR-385R-ST-A Manual de Instruções Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 9
A - 9
(7) Auxiliary equipment and options
(a) The no-fuse breaker and magnetic contactor used should be the EN or IEC standard-compliant
products of the models described in section 13.2.2.
(b) The sizes of the cables described in section 13.2.1 meet the following requirements. To meet the
other requirements, follow Table 5 and Appendix C in EN60204-1.
Ambient temperature: 40 (104) [ ( )]
Sheath: PVC (polyvinyl chloride)
Installed on wall surface or open table tray
(c) Use the EMC filter for noise reduction.
(8) Performing EMC tests
When EMC tests are run on a machine/device into which the servo amplifier has been installed, it
must conform to the electromagnetic compatibility (immunity/emission) standards after it has
satisfied the operating environment/electrical equipment specifications.
For the other EMC directive guidelines on the servo amplifier, refer to the EMC Installation
Guidelines(IB(NA)67310).
Vista de página 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 401 402

Comentários a estes Manuais

Sem comentários