4 - 3
4 AUXILIARY AND APPLIED FUNCTIONS
(4) When the multiple watch data, ON region, output enable/disable bit and forced
output bit are set to the same output device, the logical add of output results of the
settings is output.
ON
Enable/disable bit
Output device
Watch data value
ON region setting
Output device
Output OFF Output OFF
Output ON
(Forced output)
Output control based on
ON Value and OFF Value
2) With output enable/disable bit/forced output settings
1) Without output enable/disable bit/forced output settings
SM500
OFF Value
ON Value
Forced output bit
Output OFF
Output control based on
ON Value and OFF Value
Output OFF
Output ON
(Forced output)