Vista de página 204
8 - 20
8 OUTPUT MODULE
(f) An example of an address mode clutch operation is shown below.
10000 100000 00
20000
20000
10000
0
1 axis
Number of pulses per revolution : 20000[PLS]
Set the clutch ON/OFF
in this current value.
(Current value within 1
virtual axis revolution)
1 axis
Virtual servomotor current value
of auxiliary input axis side
(Synchronous encoder)
Current value within 1 virtual
axis revolution of auxiliary input
axis side
Set the clutch status
Clutch ON address = 0
Clutch OFF address = 10000
Output axis current value
Current value within 1 output
axis revolution
(Note): The rotation of output axis is reversed by differential gear.
[degree]
359.99999
Operation example
Main shaft side clutch OFF
POINT
When the number of pulses per virtual axis revolution is not an integer value, a
virtual axis revolution may not become a rotary table revolution.
Vista de página 204
1 2 ... 200 201 202 203 204 205 206 207 208 209 210 ... 315 316

Comentários a estes Manuais