The contents of this literature are as of Apr. 2010
This catalog is printed with soy ink.
MGS-FB-1004-EN-C
http://www.magnescale.com
Feedback Scale General Catalog
Shinagawa Intercity Tower A-18F, 2-15-1, Konan, Minato-ku, Tokyo 108-6018, JAPAN
Magnescale Co., Ltd.
Headquaters
Tokyo Office
Nagoya Office
Osaka Office
International Sales Department
Magnescale Americas Inc.
Magnescale Europe GmbH
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
2-35-16, Meieki, Nakamura-ku, Nagoya Aichi, 450-0002, JAPAN
2-14-6, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan
5740 Warland Drive, Cypress, CA 90630, USA
Antoniusstrasse 14, 73249 Wernau, Germany
TEL.+81 (0)463-92-1011
TEL.+81 (0)463-92-7972
TEL.+81 (0)52-587-1823
TEL.+81 (0)6-6305-3101
TEL.+81 (0)463-92-7971
TEL.+1 (949) 770-8400
TEL.
+49 (0) 7153 934 291
FAX.+81 (0)463-92-1012
FAX.+81 (0)463-92-7978
FAX.+81 (0)52-587-1848
FAX.+81 (0)6-6304-6586
FAX.+81 (0)463-92-7978
FAX.+1 (949) 770-8408
FAX.
+49 (0) 7153 934 240
:
:
:
:
:
:
:
Magnescale Co., Ltd.
Feedback scale
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - Feedback scale

The contents of this literature are as of Apr. 2010This catalog is printed with soy ink.MGS-FB-1004-EN-Chttp://www.magnescale.comFeedback Scale Genera

Página 2 - Contents

The transport plate does not set the installation standard for the rotary magnescale. Perform the installation by following section 5-1, “Installation

Página 3 - The advantage of scales

Installation Procedure 1. Check that there is no dust or scratches on the rotary magnescale installation surface. Check that there are no indentat

Página 4 - Selection Guide

SR87This robust type magnetic absolute scale system that outputs position signals for machine toolsand other equipment that require high-precision pos

Página 5 - Measurement Principle

Dimensions SR87Cable Direction RightUnit : mmDimensions SR87Cable Direction LeftUnit : mm1402403404405406407408409401040114012402783784785786787788789

Página 6 - Figure 1 Figure 2

SR84/85This robust medium type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision posi

Página 7 - Accuracy Traceability

Dimensions SR84/85Cable Direction RightDimensions SR84/85Cable Direction Left1402403404405406407408409401040114012402783784785786787788789781078117812

Página 8 - Installation method

SR77This slim type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision positioning.• Me

Página 9 - Linear Scale SR77

Dimensions SR77Cable Direction RightDimensions SR77Cable Direction Left70120170220270320370420470520570620720208258308358408458508558608658708758858L1

Página 10

SR74/75This slim type magnetic scale systemthat outputs position signals for machine toolsand other equipment that requirehigh-precision positioning.•

Página 11 - Mechanical Specifications

Dimensions SR74/75Cable Direction RightDimensions SR74/75Cable Direction Left7012017022027032037042047052057062072020825830835840845850855860865870875

Página 12 - Divisions

Magnescale technology essential for high-performance machine tools Magnescale, which was developed based on Magnescale’s advanced magnetic technology,

Página 13 - Dimensions SR87

SL110 SL13051.5/ 2.03N x 300/ 11.81P1Measuring length (L)51.5/2.03Overall length : L + 103/ 4.0610.5/ 0.419/ 0.3510.5/0.41Clamp(included)4.1/0.161 x 6

Página 14

Integrated reader head and Interpolator unit for position controlPLPL81/PL82• Compact design• Interpolator unit for automated position control• High r

Página 15 - Dimensions SR84/85

Head cable unitPLPL101 Series• Non-contact detection• Magnetic detection system for excellent resistance to dust, oil, vibrations and shocks.• Dete

Página 16

Digital ScalesRotary scaleRU77RS31044 45

Página 17 - Dimensions SR77

RU77High precision absolute rotary type with exellent resistance to environments.• System accuracy : ± 2.5sec• Output wave number : 212 = 4,096• Ou

Página 18

MJ100/110MJ620MJ820/821MJ830/831InterpolatorsRotary scale for feedback applicationsRSRS310• Magnetic principle• Excellent resistance to workshop condi

Página 19 - Dimensions SR74/75

Compact one-axis module with analog input portMJMJ620• Divides analog input signal into 32 to 800 divisions.• Produces AB quadrature signal output fro

Página 20 - SL110/SL130

Interpolator for Mitsubishi MR-J2 Super Series amplifierMJMJ830/831• Connectable to any general analog-output encoder. Input impedance: 120 Ω 1 Vp-

Página 21 - PL20C/PL25

ContourProtocol Standard Mitsubishi FanucModelCH33-**○▽CH33-**○▽ZACH33-**○▽LCH33-**○▽LACH33-**○▽MCH33-**○▽MACH33-**○▽E/PCH33-**○▽EA/P

Página 22 - Specifications

The total quality control system that operates throughout the entire design and production process ensures products with enhanced safety, high quality

Página 23 - Digital Scales

What is Magnescale?A scale is mainly used for machine tools and detects theposition of a component such as the stage to which it is installed.Feeding

Página 24 - RU77-4096A

http://www.mgscale.com58 59

Página 25 - Interpolators

Selection GuideAccuracy3+3ML/1,000μmp-p5+5ML/1,000μmp-p3+3ML/1,000μmp-p5+5ML/1,000μmp-pMeasurement length(ML: mm)70mm-2,040mm140mm-3,040mmTypeSR77SR75

Página 26 - MJ100/110

Figure 1 Arrangement of MR element and magnetic mediaHXISNMR element (X)Figure 2 Structure of high-precision MagnescaleMetal base Magnetic mediaMR e

Página 27 - MJ820/821

000100 1101λIncrementalsignalM code00010010Incremental signal detection Absolute signal detection Sin Cosbit1 2 3 4...Output signal- Wavelength: 40, 8

Página 28 - List of Adopter Cables

The He-Ne stabilized laser, the standard for accuracy measurement, is frequency calibrated in-house using the “633-nm iodine molecular absorption line

Página 29 - Connection Cable

3. Bring the scale into contact with the stop surfaces and install.Installation exampleScale installation accuracy is improved when a stop surface

Página 30

Air injection and oil lubrication In the standard configuration, the end cap section is provided with an M5 tap hole for air injection and oil lubric