Página 1 - FR-A 500

FR-A 500Frequency InverterInstallation ManualFR-A 540 ECFR-A 540L-G ECArt. No: 15434612 01 2004Version AMITSUBISHI ELECTRICINDUSTRIAL AUTOMATIONMITSUB

Página 2 - About this Manual

NOTES Special notes referring to the table:At 150% rating a maximum ambient temperature of 40°C is allowed and the PWM carrierfrequency must be less

Página 3 - Contents

2.2 Model Specifications FR-A 540L-GPlease observe the notes on page 13!SpecificationsFR-A 500 EC 11TypeFR-A 540LG75 k G90 k G110 k G132 k G160 k G220

Página 4 - Safety instructions

Please observe the notes on page 13!Specifications12 MITSUBISHI ELECTRICTypeFR-A 540LG75 k G90 k G110 k G132 k G160 k G220 k G280 k G375 k G450 kContr

Página 5

NOTES Special notes referring to the table:The applicable motor capacity refers to a motor voltage of 400V, a maximum ambient tem-perature of 40°C an

Página 6

3 Appearance and Structure3.1 Description of the Case3.1.1 Model Type FR-A 540Depending on the capacity class the frequency inverter is delivered in f

Página 7 - 1 Introduction

3.1.2 Model Type FR-A 540L-GDepending on the capacity class the frequency inverter is delivered in three different structuralshapes of the case. The f

Página 8 - 2 Specifications

4 Wiring4.1 OverviewECAUTION:The terminals PC-SD of the 24V DC power supply must not be shorted. Otherwise theinverter will be damaged.The JOG termin

Página 9 - FR-A 500 EC 9

4.2 Wiring of the Main CircuitPDANGER:The frequency inverter must always be powered off completely before performingany wiring work. To ensure that no

Página 10

NOTE It is recommended to use a shielded motor cable in order to reduce cable radiation.NOTE The maximum wiring length of the motor cable ist 300m for

Página 11 - FR-A 500 EC 11

The following table shows the terminal assignment of main circuit terminals.ECAUTION:Switching the unit off and on repeatedly with the mains power sup

Página 12 - 12 MITSUBISHI ELECTRIC

2 MITSUBISHI ELECTRICInstallation ManualFR-A 540 EC and FR-A 540L-G ECArt. No: 141712Version Changes / Additions / CorrectionsA 01/04 pdp – gb First i

Página 13

4.2.2 Separate Power Supply for the Control CircuitIn an alarm condition the frequency inverter’s integrated alarm relay only remains active as longas

Página 14 - 3 Appearance and Structure

Remove the jumpers as follows:Loosen the upper screws  and then the lower screws .Pull out and remove the jumper .Connect the seperate power sup

Página 15 - 3.1.2 Model Type FR-A 540L-G

4.3 Wiring of the Control CircuitThe following picture shows the arrangement of the terminal for the control circuit of the inverter.Wiring22 MITSUBIS

Página 16 - 4 Wiring

WiringFR-A 500 EC 23Terminal Terminal name DescriptionCommonSDCommon sink for contactinput/reference potentialA determined control function is activat

Página 17 - Wiring of the Main Circuit

Wiring24 MITSUBISHI ELECTRICTerminal Terminal name DescriptionSignaloutputsA, B, CPotential freealarm outputThe alarm is output via relay contacts. Th

Página 18 - 500m from 0.75 k upwards

ECAUTION:Terminals 10/10E and 5 must not be connected to each other. Otherwise the internalvoltage output for the connection of the potentiometer will

Página 19 - FR-A 500 EC 19

5 Parameters5.1 Overview and Setting RangesParameters26 MITSUBISHI ELECTRICFunc-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G

Página 20 - Control circuit

ParametersFR-A 500 EC 27Func-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GStandardoperationfunctions24Mu

Página 21

Parameters28 MITSUBISHI ELECTRICFunc-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GOperationselectionfunc

Página 22 - Wiring of the Control Circuit

ParametersFR-A 500 EC 29Func-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-G5-pointflexible V/fcharacter-i

Página 23 - FR-A 500 EC 23

FR-A 500 EC 3Contents1 Introduction1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 24 - 24 MITSUBISHI ELECTRIC

Parameters30 MITSUBISHI ELECTRICFunc-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GBacklash140Backlash ac

Página 25

ParametersFR-A 500 EC 31Func-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GUserfunctions173User group 1 r

Página 26 - 5 Parameters

Parameters32 MITSUBISHI ELECTRICFunc-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GSupple-mentaryfunction

Página 27 - FR-A 500 EC 27

ParametersFR-A 500 EC 33Func-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GParameteroptions306Analog outp

Página 28 - 28 MITSUBISHI ELECTRIC

Parameters34 MITSUBISHI ELECTRICFunc-tionPara-meterMeaningSetting range Default settingFR-A 540 FR-A 540L-G FR-A 540 FR-A 540L-GParameteroptions350Sto

Página 29 - FR-A 500 EC 29

Remarks on the table:The parameter setting is ignored, if the advanced flux vector control is activated.Can only be set, if parameters 80 and 81 do

Página 30 - 30 MITSUBISHI ELECTRIC

6 Protective Functions6.1 Error Messages and RemediesProtective Functions36 MITSUBISHI ELECTRICError MessageMeaning Description RemedyControl PanelFR-

Página 31 - FR-A 500 EC 31

Error MessageMeaning Description RemedyControl PanelFR-PU04ControlPanelFR-DU04Inst.Pwr.LossInstantaneouspower failure pro-tectionThe output of the inv

Página 32 - 32 MITSUBISHI ELECTRIC

Error MessageMeaning Description RemedyControl PanelFR-PU04ControlPanelFR-DU04CorruptMemryMemory errorError on access of the data mem-ory of the inver

Página 33 - FR-A 500 EC 33

Error MessageMeaning Description RemedyControl PanelFR-PU04ControlPanelFR-DU04—Brake resistoroverloadThe brake resistor must ex-change too much energy

Página 34 - 34 MITSUBISHI ELECTRIC

Safety instructionsFor qualified staff onlyThis manual is only intended for use by properly trained and qualified electrical technicians whoare fully

Página 35

7 Dimensions7.1 Inverter Type FR-A 5407.1.1 Capacity Classes 0.4 k to 3.7 kNOTE The inverters FR-A 540 EC-0.4 k to 1.5 k do not have a built-in fan.7.

Página 36 - 6 Protective Functions

7.1.3 Capacity Classes 30 k to 55 kDimensionsFR-A 500 EC 41AC3,22-øCmmBDB1A1A2EType A A1 A2 B B1 C D EFR-A 540-30 k 340 270 320 550 530 195 71.5 10FR-

Página 37 - FR-A 500 EC 37

7.2 Inverter Type FR-A 540L-G7.2.1 Capacity Classes G75 k to G110 k7.2.2 Capacity Classes G132 k to G280 kDimensions42 MITSUBISHI ELECTRIC480 3603,24-

Página 38 - 38 MITSUBISHI ELECTRIC

7.2.3 Capacity Classes G375 k and G450 kDimensionsFR-A 500 EC 43Unit: mm949656565654-ø301100 5001900805620107582565653530

Página 39

HEADQUARTERSMITSUBISHI ELECTRIC EUROPEEUROPE B.V.German BranchGothaer Straße 8D-40880 RatingenPhone: +49 (0)2102 486-0Fax: +49 (0)2102 486-1120e mail:

Página 40 - 7 Dimensions

General safety information and precautionsThe following safety precautions are intended as a general guideline for using the frequencyinverter togethe

Página 41 - FR-A 500 EC 41

Safety warningsIn this manual special warnings that are important for the proper and safe use of the products areclearly identified as follows:PDANGER

Página 42 - Inverter Type FR-A 540L-G

1 IntroductionThis Installation Manual includes a brief summary of the main specifications of the FR-A 500 fre-quency inverters, which should be suffi

Página 43 - FR-A 500 EC 43

2 Specifications2.1 Model Specifications FR-A 540Please observe the notes on page 10!Specifications8 MITSUBISHI ELECTRICTypeFR-A 5400.4 k 0.75 k 1.5 k

Página 44 - INDUSTRIAL AUTOMATION

Please observe the notes on page 10!Specifications SpecificationsFR-A 500 EC 9TypeFR-A 5400.4 k 0.75 k 1.5 k 2.2 k 3.7 k 5.5 k 7.5 k 11 k 15 k 18.5 k