eWON Application User Guide
AUG 032 / Rev 1.0
You Select, We Connect
eVCOM
Standard serial communications
Content
eVCOM is the Virtual COM software for eWON.
With eWON and eVCOM software, you can achieve long distance access to a serial device by
creating, on your computer, a virtual COM port linked to an eWON placed beside your serial
device.
Vista de página 0
1 2 3 4 5 6 ... 28 29

Resumo do Conteúdo

Página 1 - You Select, We Connect

eWON Application User GuideAUG 032 / Rev 1.0You Select, We ConnecteVCOMStandard serial communicationsContenteVCOM is the Virtual COM software for eWON

Página 2 - Table of Contents

eVCOM configuration Chapter 5.5. eVCOM configurationStart the eVCOM application.You need to create a Virtual Port. Use the Add Port button to create

Página 3 - Software requirements

5. eVCOM configurationAnd configure it.(1) The Gateway address is the IP address where you can reach the eWON (either by your LAN network, either by a

Página 4 - Introduction

5. eVCOM configurationOnce enabled, eVCOM will show your new COM port like following:Note: - the icon is when the COM port is enabled- the icon is

Página 5 - VCOM Protocols handled

General Remote Access to the Device Chapter 6.6. General Remote Access to the DeviceYour Device is linked to the eWON.The connection to the eWON is es

Página 6

6. General Remote Access to the DeviceReturning to the eVCOM software, selecting your COM port and viewing the Status tab will show like below:Notice

Página 7

Practical examples Chapter 7.7. Practical examplesDirect Ethernet VCOM to a Mitsubishi PLCFor this example, we want to reach a Mitsubishi PLC placed b

Página 8 - 4. eWON Serial Configuration

7. Practical exampleseVCOM configurationOn the computer, create a Virtual port in the eVCOM software and set the “Gateway address” to the eWON IP addr

Página 9

7. Practical examplesMitsubishi Melsoft configurationOpen the Melsoft program and create a new project.Goes in the “Transfer Setup” menu.eVCOM (Standa

Página 10 - 5. eVCOM configuration

7. Practical examplesConfigure the Serial interface on the Virtual Port created with eVCOM.And test the connection.Congratulations, you can now progra

Página 11

7. Practical examplesDirect Phone VCOM to a TwidoThe remote connection that we will use in this example is a “Direct Phone Connection”. This connectio

Página 12

Table of Contents1. Hardware and software requirements...

Página 13

7. Practical exampleseWON configuration for Remote ConnectionAccess to eWONAccessing your eWON is very simple:Enter the IP address of your eWON in the

Página 14

7. Practical examplesCheck the Server enabled box for the PPP Incoming Connection.Let the eWON PPP server IP address and the PPP client IP address unc

Página 15 - Practical examples

7. Practical examplesEstablish the remote connectionOn your PC you will need to create a dial-up connection.You can create a standard dial-up connecti

Página 16 - IMPORTANT

7. Practical examplesLaunch the eCatcher application (eCatcher.exe)Select the «My connection» tab (not the Talk2M tab). Click on «Add a Dial-up entry»

Página 17 - Setup” menu

7. Practical examplesGo to the Action tab:This window will allow you to configure the action that will be performed once the remote connection is esta

Página 18

7. Practical examplesThe Dial-up connection that you have created will now appear in the list of «eWONs -Dial-up». To start the remote connection foll

Página 19 - Direct Phone VCOM to a Twido

7. Practical examplesSerial eWON configurationOn the eWON, as the Twido PLC uses a RS-485 serial link, you will configure the eWON serial dipswitch in

Página 20 - Access to eWON

7. Practical exampleseVCOM configurationOn the computer, create a Virtual port in the eVCOM software and set the Gateway address to the eWON IP of the

Página 21

7. Practical examplesTwidosoft configurationNow, in the Twidosoft software, you need to create a connection to the Virtual port created in eVCOM.Open

Página 22 - Using eCatcher

RevisionsRevision Level Date Description1.0 08/12/2009 First release.i Microsoft, Internet Explorer, Windows and Windows XP are either registered trad

Página 23

Hardware and software requirements Chapter 1.1. Hardware and software requirementsHardware requirementsIn order to follow this guide you'll need:

Página 24

Introduction Chapter 2.2. IntroductioneVCOM is the Virtual COM software for eWONThe eWON family is a range of Industrial Gateways designed to perform

Página 25 - Company XXXX – Production

2. IntroductionWhen your applicative software sends a serial command to the virtual port, this command will be packaged in a TCP/IP frame and will be

Página 26 - Serial eWON configuration

eWON IP address configuration Chapter 3.3. eWON IP address configurationEvery eWON™ is shipped with the pre-configured IP address 10.0.0.53 and adm/ad

Página 27

3. eWON IP address configurationEnter the eWON serial number in the Serial Number field if you know it, or click on the Browse button. In this case, t

Página 28 - Twidosoft configuration

eWON Serial Configuration Chapter 4.4. eWON Serial ConfigurationConnect your Serial Device to the serial port of your eWON.In eWON, you need to config

Página 29 - Document build number: 15

4. eWON Serial ConfigurationFor simple serial communication, you need only - to select the eWON port (COM1 for the serial port)- to set the Port Type