Mitsubishi X30 Especificações

Consulte online ou descarregue Especificações para Projetores Mitsubishi X30. Mitsubishi X30 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
www.m16canz.com
1
MITSUBISHI M16C/62 MCU
STARTER KIT BOARD
(MSA0654-MEAUST)
INSTALLATION PROCEDURE
Version 2.0
06-Jun-02
Prepared by Alan Suyko
Vista de página 0
1 2 3 4 5 6 ... 13 14

Resumo do Conteúdo

Página 1 - INSTALLATION PROCEDURE

www.m16canz.com 1 MITSUBISHI M16C/62 MCU STARTER KIT BOARD (MSA0654-MEAUST) INSTALLATION PROCEDURE Version 2.0 06-Jun-02 Prepared by

Página 2

www.m16canz.com 10 8. Click the BPR button to perform Blank Check, Program and Read Check on the specified address range (0FE000 to 0FFFFF) fo

Página 3

www.m16canz.com 11 2. When this is done for the first time, TM will ask you to select a debug tool. Make sure KD30 is already installed prior

Página 4

www.m16canz.com 12 Once the project files are downloaded to KD30, you are now ready to perform your code debugging and evaluation in KD30 using i

Página 5

www.m16canz.com 13 b. Enter the file path of lmc30 (normally C:\Mtool\BIN\lmc30.exe). c. Enter ‘%X’ in the Parameters field. This will pass the

Página 6

www.m16canz.com 14 3. Click on the Erase button to erase the Monitor Program contained in the Flash ROM. 4. Click the BPR button to perform Bl

Página 7

www.m16canz.com 2 I. SOFTWARE TOOL VERSIONS: C Compiler: NC30WA Version 5.00 Release 1 or later Integrated Development Environment: Tool

Página 8

www.m16canz.com 3 III. PROJECT CREATION PROCEDURE: 1. Run Tool Manager 3.11 (TM Project Bar). Create a new project by clicking the New Project b

Página 9

www.m16canz.com 4 • Select the .x30 file and add the C source file (e.g. sample3.c) to your newly created project by clicking the Add File butt

Página 10 - KD30 Debugging

www.m16canz.com 5 4. If no errors were found, you are now ready to debug your new project. IV. TEXT EDITOR SETUP: Tool Manager does not com

Página 11

www.m16canz.com 6 3. Verify if EditPlus is setup correctly by going to TM Project Editor window and double clicking your C source file in the pro

Página 12

www.m16canz.com 7 Flash Start Setup 1. Register Flash Start in Tool Manager by clicking the Tool Register button. 2. Select the Application

Página 13

www.m16canz.com 8 3. Connect the DC power supply (either 9V or 5V) to the board. The black DC socket is center-positive and accepts DC voltage

Página 14

www.m16canz.com 9 6. From the main menu below, click on Setting to change the baud rate to a faster speed. If you are using a 16MHz crystal on b

Comentários a estes Manuais

Sem comentários